FlexReport for WinForms
StdDequantizerParams クラス メンバ
フィールド  メソッド 


C1.Win.C1Document.4.5.2 アセンブリ > GrapeCity.Documents.Imaging.jpeg.jj2000.j2k.quantization.dequantizer 名前空間 : StdDequantizerParams クラス

StdDequantizerParamsデータ型で公開されるメンバを以下の表に示します。

パブリック コンストラクタ
 名前解説
Public コンストラクタ  
トップ
パブリック フィールド
 名前解説
Public フィールドThe quantization step "exponent" value, for each resolution level and subband, as it appears in the codestream. The first index is the resolution level, and the second the subband index (within the resolution level), as specified in the Subband class. When in derived quantization mode only the first resolution level (level 0) appears.

For non-reversible systems this value corresponds to ceil(log2(D')), where D' is the quantization step size normalized to data of a dynamic range of 1. The true quantization step size is (2^R)*D', where R is ceil(log2(dr)), where 'dr' is the dynamic range of the subband samples, in the corresponding subband.

For reversible systems the exponent value in 'exp' is used to determine the number of magnitude bits in the quantized coefficients. It is, in fact, the dynamic range of the subband data.

In general the index of the first subband in a resolution level is not 0. The exponents appear, within each resolution level, at their subband index, and not in the subband order starting from 0. For instance, resolution level 3, the first subband has the index 16, then the exponent of the subband is exp[3][16], not exp[3][0].

 
Public フィールドThe quantization step for non-reversible systems, normalized to a dynamic range of 1, for each resolution level and subband, as derived from the exponent-mantissa representation in the codestream. The first index is the resolution level, and the second the subband index (within the resolution level), as specified in the Subband class. When in derived quantization mode only the first resolution level (level 0) appears.

The true step size D is obtained as follows: D=(2^R)*D', where 'R=ceil(log2(dr))' and 'dr' is the dynamic range of the subband samples, in the corresponding subband.

This value is 'null' for reversible systems (i.e. there is no true quantization, 'D' is always 1).

In general the index of the first subband in a resolution level is not 0. The steps appear, within each resolution level, at their subband index, and not in the subband order starting from 0. For instance, if resolution level 3, the first subband has the index 16, then the step of the subband is nStep[3][16], not nStep[3][0].

 
トップ
パブリック メソッド
 名前解説
Public メソッドオーバーライドされます。 Returns the type of the dequantizer for which the parameters are. The types are defined in the Dequantizer class.  
トップ
参照

StdDequantizerParams クラス
GrapeCity.Documents.Imaging.jpeg.jj2000.j2k.quantization.dequantizer 名前空間
GrapeCity.Documents.Imaging.jpeg.jj2000.j2k.quantization.dequantizer.StdDequantizer